Exogenous recombinant human insulin-induced severe hypersensitivity reaction precipitating hyperglycemic crisis: A clinical conundrum. | Department of Endocrinology, Diabetes & Metabolism
Order Books Courses Offered
+91 416 228 2528
CMC Logo
Department of Endocrinology, Diabetes & Metabolism
Christian Medical College Vellore
Department of Endocrinology Christian Medical College Vellore
Book
Appointment
Patient
Services
Admissions
Site Map Order Books
Department of Endocrinology, Diabetes & Metabolism
Christian Medical College Vellore
Not to be ministered unto but to minister
News

The Department of Endocrinology, Christian Medical College Vellore has launched its official Endocrinology CMC Vellore Android app now available on the Google Play Store — users can download it to access the latest department updates, academic resources, event notifications, and educational materials on diabetes and endocrine care.

Exogenous recombinant human insulin-induced severe hypersensitivity reaction precipitating hyperglycemic crisis: A clinical conundrum.

  1. Department of Endocrinology, Diabetes and Metabolism, Christian Medical College (CMC) Vellore, Tamil Nadu, India.

Journal of family medicine and primary care Vol. 9 · Issue 8 · pp. 4470-4472

PMID 33110889 DOI 10.4103/jfmpc.jfmpc_148_20

Cite This Article

K U Lijesh, Riddhi Das Gupta, M SenthilRaja, Nitin Kapoor, Thomas V Paul, Nihal Thomas. Exogenous recombinant human insulin-induced severe hypersensitivity reaction precipitating hyperglycemic crisis: A clinical conundrum. Journal of family medicine and primary care. 2020;9(8):4470-4472. doi:10.4103/jfmpc.jfmpc_148_20

Abstract

Hypersensitivity reactions against exogenous insulin are a rare clinical entity after the advent of recombinant human insulin; however, there are still case reports wherein patients develop hypersensitivity reactions against insulin. We present the case of a type 1 diabetes mellitus patient who developed type 1 hypersensitivity reaction against subcutaneous insulin. He had recurrent episodes of diabetic ketoacidosis after developing hypersensitivity reactions against insulin, requiring multiple hospital admissions. When he presented to us, he was on both insulin infusion and subcutaneous insulin, requiring a daily insulin dose of about 800 units and having severe insulin hypersensitivity reactions and hyperglycemia. He had multiple subcutaneous erythematous nodules at the insulin injection sites, however, had no evidence of systemic allergy. Investigations revealed eosinophilic leukocytosis, and high IgE levels and skin biopsy showing evidence of insulin hypersensitivity. He was desensitized to insulin according to Heinzerling . insulin desensitization protocol and subsequently with immunomodulation therapy using steroids (pulse methylprednisolone) and mycophenolate mofetil as well as by installation of insulin pump.

Keywords

  • Desensitization protocol
  • immunomodulation
  • insulin hypersensitivity
  • insulin pump
MAKE AN APPOINTMENT
CMC Endocrinology
Add to your Home Screen for quick access

Tap the Share button in your browser

then select "Add to Home Screen"

CMC Endocrinology

CMC Endocrinology

CMC Vellore

🔔 Notifications

← Back to notifications