Dual-Energy X-Ray Absorptiometry Scanning in Practice, Technical Aspects, and Precision Testing. | Department of Endocrinology, Diabetes & Metabolism
Order Books Courses Offered
+91 416 228 2528
CMC Logo
Department of Endocrinology, Diabetes & Metabolism
Christian Medical College Vellore
Department of Endocrinology Christian Medical College Vellore
Book
Appointment
Patient
Services
Admissions
Site Map Order Books
Department of Endocrinology, Diabetes & Metabolism
Christian Medical College Vellore
Not to be ministered unto but to minister
News

The Department of Endocrinology, Christian Medical College Vellore has launched its official Endocrinology CMC Vellore Android app now available on the Google Play Store — users can download it to access the latest department updates, academic resources, event notifications, and educational materials on diabetes and endocrine care.

Dual-Energy X-Ray Absorptiometry Scanning in Practice, Technical Aspects, and Precision Testing.

  1. Department of Endocrinology, Christian Medical College, Vellore, Tamil Nadu, India.
  2. Department of Gynaecology, Tanvir Hospital, Hyderabad, Telangana, India.

Journal of mid-life health Vol. 12 · Issue 4 · pp. 252-256

PMID 35264829 DOI 10.4103/jmh.jmh_215_21

Cite This Article

Kripa Elizabeth Cherian, Nitin Kapoor, Meeta Meeta, Thomas Vizhalil Paul. Dual-Energy X-Ray Absorptiometry Scanning in Practice, Technical Aspects, and Precision Testing. Journal of mid-life health. 2021;12(4):252-256. doi:10.4103/jmh.jmh_215_21

Abstract

The last three decades have witnessed considerable progress in the field of bone densitometry. Osteoporosis may be diagnosed in postmenopausal women and in men aged 50 and older if the bone mineral density (BMD) T-scores of the lumbar spine, total hip, or femoral neck are -2.5 or less. For reporting T-scores, the Hologic dual-energy X-ray absorptiometry (DXA) scanner uses the Caucasian (nonrace adjusted) female normative database for women and men of all ethnic groups although reference database used does have an impact on the categorization of BMD and must be chosen judiciously considering the regional and ethnic characteristics of the population. The quality control for DXA systems should be periodically done in accordance with manufacturer guidelines for DXA. Beyond conventional BMD assessment, DXA may also be utilized to assess the trabecular bone score, hip structural analysis, vertebral fractures, and body composition.

Keywords

  • Bone mineral density
  • database
  • dual-energy X-ray absorptiometry
  • hip structural analysis
  • quality control
  • trabecular bone score TBS